BURNER DISPOSITION
Burners
Operating
Pressure Gas
Rate
Diameter
Injectors
Heat Input By-pass
N. Denomination mbar g/h l/h 1/100 mm Min Max 1/100 mm
2 Rapid
LPG gas
Natural gas
30
20
218 286
88
117-Y
800
800
3000
3000
44
3 Semi-rapide
LPG gas
Natural gas
30
20
131 171
68
98-Z
600
600
1800
1800
34
4 Auxiliary
LPG gas
Natural gas
30
20
73 95
51
75-X
400
400
1000
1000
28
6 Ultra-rapide central
LPG gas
Natural gas
30
20
276 362
98
135-K
1400
1400
3800
3800
65
TECHNICAL FEATURES
Description Nominal data
Lower heating element of the oven cooker
Top heating element of the oven-grill cooker
Rear heating element type cooker
Spit motor
Oven lamp
Rear fan
Cooling fan
Cable type
1700 W
1400 + 2000 W
3000 W
4 W
15 W - E 14 – T 300
25..29 W
12 W
H05 RR-F 3x1.5 mm
2