GB4
REPLACING THE INJECTORS (see the injector table in the Instruction)
ADJUSTING MINIMUM GAS SETTING OF TAPS
REFERENCE TO LOCAL REGULATIONS
Provision for ventilation
The room in which the appliance is installed must have an air supply to current B.S. 5440 - Part 2 standards.
All rooms require a permanent vent in addition to the openable window.
If there are other fuel burning appliances in the same room B.S. 5440 - Part 2 should be consulted to determine the air vent
requirements.
If the appliance is installed in a cellar or basement, it is advisable to provide an air vent of 65 cm, irrespective of the room
volume.
Gas Safety Regulations
The law requires that all gas appliances are installed by competent persons in accordance with the current gas safety
regulations. Failure to install appliances correctly may lead to prosecution.
It is in your own interest, and that of safety, to ensure that the law is complied with. The hob should be installed in
accordance with the Gas Safety (Installation and Use) Regulations, the Building Regulations issued by the Department
of the Environment and the Building Standard (Scotland) (Consolidation) Regulations, issued by the Scottish
Development Department.
In the G.B., CORGI registered installers work to safe standards of practice.
•Remove grids (A).
•Extract burners (B).
Using a socket spanner of the appropriate size
unscrew the injector (C), unscrew the injector to be
replaced.
Replace it with the injector suitable for the new
type of gas.
Re-assemble the injector in (D).
If you have a multiple crown burner use side
spanner to replace the injector (E).
Before installing the hob, remember to affix the gas
calibration plate supplied with the injectors in such a way
that it covers the existing information relating to gas
calibration.
To ensure that the minimum setting is correctly adjusted, remove the knob and
proceed as follows:
tighten screw to reduce the flame height (-);
loosen screw to increase the flame height (+).
The adjustment must be performed with the tap in minimum gas setting position
(small flame) .
The primary air of the burners does not need to be adjusted.
At this stage, light up the burners and turn the knobs from max position to
minimum position to check flame stability.
Upon completion of adjustment, reseal using sealing wax or an equivalent material.