Vacuum-pumping and Leakage Inspection
1. Remove the nut cover at the shutoff valve.
2. Align with the center of the fitting pipe and
manually tighten the conical nut sufficiently.
3. Use a wrench to tighten the conical nut.
4. Remove the liquid valve cap, the gas valve cap
and the nut of refrigerant inlet.
5. Use an Allen wrench to twist off the liquid valve
body and at the same time use screwdriver to
open the valve core of the liquid valve. Now gas
will flow out.
6. After the gas continues flowing for about 15
second and refrigerant gas begins to flow out,
close the valve core and tighten the nut of
refrigerant inlet.
7. Completely open the valve body of the liquid
valve and the gas valve.
8. Turn and tighten the valve cap, then use soapy
water or a leak detector to check for gas
leakage at the outdoor and indoor units and
pipeline connections.
9. If conditions permit, use a vacuum pump to
pump air in the unit from the valve core.
Draining of Condensate Water of Outdoor
Unit
When the air-conditioning unit is in the heating
mode, the condensate water generated at the
outdoor unit and the water generated by
defrosting drains through the drainage pipe to the
outlet.
Installation methods: as shown in the figure, insert
the drainage joint of the outdoor unit into the Ø
25 hole on the base plate.
Connect the drainage pipe to the drainage outlet
so as to drain the condensed water and water
generated by defrosting to proper place.
Vacuum Gauge
Small Pipe
Big Pipe
Valve Cap
Vacuum Pump
Refrigerant
Change Mouth
Liquid Pipe
Liquid Valve
Inner Hexagon
Wrench
Gas Pipe
Gas Valve
Chassis
Outdoor Drainage Tap