104
INSTRUCTIONS FOR USE
SINGLE SPLIT AIR CONDITIONER WITH
GAS R410A / R410A INVERTER
PRECAUTIONS FOR USE
SPECIFICATIONS AND TECHNICAL DATA
(DEPENDING ON THE MODEL)
INSTRUCTIONS FOR USE
DESCRIPTION OF AIR CONDITIONER
COMPONENTS
HOW TO USE REMOTE CONTROL
CLEANING AND MAINTENANCE
TROUBLESHOOTING
INSTALLATION SERVICE - PRECAUTIONS
ON INSTALLATION
ELECTRICAL SAFETY REQUIREMENTS
INSTALLATION DIMENSION DRAWINGS
INSTALLING INDOOR UNIT
CHECKS AND TEST RUN AFTER INSTALLATION
ELECTRIC HEATING BELT
ELECTRICAL CONNECTION
Thank you for selecting a Whirlpool air conditioner. For best results, please keep this Manual properly for
future reference.
This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE).
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for
the environment and human health, which could otherwise be caused by inappropriate waste handling of this
product.
The symbol on the product, or on the documents accompanying the product, indicates that this
appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment.
Disposal must be carried out in accordance with local environmental regulations for waste disposal.
For more detailed information about treatment, recovery and recycling of this product, please contact your
local city office, your household waste disposal service or the shop where you purchased the product.
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - INSTRUCTIONS FOR USE

104INSTRUCTIONS FOR USESINGLE SPLIT AIR CONDITIONER WITH GAS R410A / R410A INVERTERPRECAUTIONS FOR USESPECIFICATIONS AND TECHNICAL DATA (DEPENDING ON

Page 2 - PRECAUTIONS FOR USE

113HOW TO USE REMOTE CONTROLOperating Guideline - General Procedures 1.After the main unit is connected to power, press the ON/OFF key on the remote c

Page 3

114UP/DOWNUP/DOWN KeyPress these two keys when in COOL, DRY, FAN or HEAT mode to set a temperature between 16 and 30°C. The temperature of each mode c

Page 4 - (DEPENDING ON THE MODEL)

115JETJET keyIn COOL or HEAT mode, press this key to activate or disable the jet function. The JET icon will appear when the jet function is activated

Page 5

116Replacement of Remote Control Battery and Precautions 1.Gently press down on the battery cover and push in the direction of the arrow to remove, as

Page 6 - COMPONENTS

117CLEANING AND MAINTENANCEWarning •Make sure to stop the unit and unplug it before cleaning your air conditioner. Otherwise you may risk electrocutio

Page 7 - Outdoor Unit

118Checks before Seasonal Use 1.Check the air inlet/outlet on indoor and outdoor units for any blocking. 2.Check the grounding cable for reliability.

Page 8

119TROUBLESHOOTINGWarning:Do not attempt to repair the air conditioner yourself. Incorrect repairs may cause electrocution or fire, so please contact

Page 9

120Malfunction CauseIndoor unit makes noise•The sound comes from the fan or compressor relay switching over (close/open). •Air conditioner may make no

Page 10 - HOW TO USE REMOTE CONTROL

121INSTALLATION SERVICE - PRECAUTIONS ON INSTALLATIONImportant Precaution1.The air-conditioning unit must be installed according to national wiring ru

Page 11 - Remote Control

122ELECTRICAL SAFETY REQUIREMENTS1.The power supply must be of rated voltage with special circuitry for air-conditioning. The diameter of the power co

Page 12

105PRECAUTIONS FOR USEWarning:•Make sure to insert the power plug securely. Insecure insertion of the plug may cause electrocution or fire. •Never unp

Page 13

123INSTALLATION DIMENSION DRAWINGSFrom the Wall From the ceiling Over 15cm Over 15cm Over 15cm From the wall Over 50cm From obstacles From the Wall Ov

Page 14 - CLEANING AND MAINTENANCE

124INSTALLING INDOOR UNIT Installing Wall-Mount Frame1.Level with plumb line or spirit level. As the drain outlet is on the left side, it is better fo

Page 15

125Notes: If the connecting cable is not long enough, please contact the authorized service center for a length of special cable. No joints are allowe

Page 16 - TROUBLESHOOTING

126Cable connection1.Remove the handle on the right side plate of the outdoor unit (one screw). 2.Remove the cable clamp, connect the power connection

Page 17 - Malfunction Cause

127Vacuum-pumping and Leakage Inspection1.Remove the nut cover at the shutoff valve. 2.Align with the center of the fitting pipe and manually tighten

Page 18 - PRECAUTIONS ON INSTALLATION

128CHECKS AND TEST RUN AFTER INSTALLATION Check Items After InstallationTest Run 1. Preparation of Test Run •Do not switch on the power before all ins

Page 19

129ELECTRICAL CONNECTION1) For Great Britain onlyWarning - this appliance must be earthedFuse replacementIf the mains lead of this appliance is fitted

Page 20

106Warning:•Do not cut or damage the power cords and control lines. Any damaged power cords and signal control lines of the air conditioner must be re

Page 21 - INSTALLING INDOOR UNIT

107SPECIFICATIONS AND TECHNICAL DATA (DEPENDING ON THE MODEL)1.The above data may change without notice. The data on the rating are accurate.2.When th

Page 22 - Right Left rear

108INSTRUCTIONS FOR USE The Principle and Special Functions of Cooling Mode Principle: The air conditioner absorbs heat from indoor air and discharges

Page 23 - AMC 996/8

109DESCRIPTION OF AIR CONDITIONER COMPONENTS Outdoor Unit1.Power plug 2.Terminal board cover plate3.Key switch 4.Front panel 5.Filter 6.Guide louver 7

Page 24 - Outdoor Drainage Tap

110The actual unit may be different than the picture shownIndoor UnitOutdoor Unit1.Key switch 2.Front panel3.Filter 4.Guide louver5.Receiving windows6

Page 25 - ELECTRIC HEATING BELT

111Signal receiverDehumidify OnTemperature Cool Heat Indoor UnitOutdoor Unit1.Power plug 2.Key switch 3.Front panel 4.Guide louver 5.Filter 6.Remote c

Page 26 - ELECTRICAL CONNECTION

112Indoor UnitOutdoor Unit1.Power plug 2.Key switch 3.Front panel 4.Guide louver 5.Filter 6.Remote control windows7.Covering plate of Terminal Board8.