Whirlpool KHMF 9010/I Mode d'emploi Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
Technical information for the installer
This product can be built into a 20 to 40 mm deep worktop.
The hob cannot be installed with an oven underneath. Always insert a separator panel under
the hob at a distance of no less than 25 mm from the lowest point (electronic control
module) on the appliance. Follow the measures shown in the “Sizes and installation
measurements (mm)” section.
Before installation, make sure that:
Warning: this is a heavy products which requires the installation to be carried out by two
people.
The local gas mains (type and pressure) and the calibration on the hob are compatible (see
serial no. plaque and injector table).
The covering on the walls of the appliance or appliances next to the hob are heat resistant in
compliance with local regulations.
The combustion smoke is released via proper suction hoods or electrical fans installed on the
walls and/or windows.
The air circulates naturally through a suitable opening that is no less than 100 cm
2
of
practicable section, which must be:
Permanent and accessible on the walls of the room being ventilated and extracting towards
the outside
Created in such a way that the openings, both inside and out, cannot be obstructed, not
even by mistake
Protected by plastic grills, metallic netting etc. that, under no condition, should reduce the
practicable section indicated above
Located close to the floor and placed in such a way that it does not interfere with the
extraction of the combustion smoke.
Installation
11
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 19 20

Commentaires sur ces manuels

Pas de commentaire