11
* At 15°C and 1013 mbar-dry gas
G31 P.C.S. = 50.37 MJ/Kg
G30 P.C.S. = 49.47 MJ/Kg
G20 P.C.S. = 37.78 MJ/m3
G110 P.C.S. = 15.87 MJ/m3
This appliance conforms to the following European Economic
Community directives:
- 73/23/EEC of 19/02/73 (Low Voltage) and subsequent modi-
fications;
- 89/336/EEC of 03/05/89 (Electromagnetic Compatibility) and
subsequent modifications;
- 90/336/EEC of 29/06/90 (Gas) and subsequent modifications;
- 93/68/EEC of 22/07/93 and subsequent modifications.
Inner Volume of the ELECTRIC Oven:
56 litres
Voltage and Frequency of Power Supply:
230V ~ 50Hz 2800W
BURNER AND NOZZLE SPECIFICATIONS
OVEN TECHNICAL SPECIFICATIONS
ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
Energy consumption for Natural convection:
heating mode: Convection
Declared energy consumption for Forced convection
Class:
heating mode: Fan assisted
Table 1 Liquid gas Natural gas City gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Flow *
g/h
Injector
1/100
(mm)
Flow*
l/h
Injector
1/100
(mm)
Flow*
l/h
Nomin. Reduc. G30 G20 G110
C.
Rapid 100 3.00 0.7 40 86 218 116 286 260 680
B. Semi-rapid 75 1.65 0.4 30 64 120 96 157 185 395
A.
Auxiliary 55 1.00 0.3 27 50 73 71 95 145 227
D. Triple Ring 130 3.25 1.3 57 91 236 124 309 285 770
Supply pressure Nominal
Minimum
Maximum
28-30
20
35
20
17
25
8
6
15