5-3
Refer to page 4-9 for the procedure for servic-
ing a broil element.
1. Disconnect the electrical power to the
double oven.
2. Disconnect the wires from the broil ele-
ment terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter leads to the broil
element terminals. The meter should indi-
cate between 15 and 20 Ω.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
WARNING
BROIL ELEMENT
Refer to page 4-10 for the procedure for servic-
ing a bake element.
1. Disconnect the electrical power to the
double oven.
2. Disconnect the wires from the bake ele-
ment terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter leads to the element
terminals. The meter should indicate be-
tween 22 & 30 Ω.
BAKE ELEMENT
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
Commentaires sur ces manuels