GB
7
SS
AR
PAN 642 IX/H
PAS 642 /H(WH)
PAS 642 /H(BK)
NATURAL GAS
(Methane)
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane)
(Propane)
G30
G31
25 37 45
Model configuration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
Rapid
Semi-Rapid
Auxiliary
Rapid
Semi-Rapid
Auxiliary
G20
F2 118
Z 95
X 72
80
60
47
Burner and nozzle specifications
Table 1
TYPE OF GAS
USED
TYPE OF
BURNER
NOZZLE RATED
THERMAL
FLOW RATE
kW
RATED
CONSUMPTION
REDUCED
HEAT
CAPACITY
kW
GAS PRESSURE
mbar
min. rat. max.
3.00
1.65
1.00
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
0.70
0.45
0.35
G20 20 mbar 1R -2SR -1AUX 7.30 695 l/h 9.52
G30/31 37 mbar 1R -2SR -1AUX 7.30 484 g/h 30.94
Type of gas used
ELECTRIC SUPPLY: 220-240V~ 50/60Hz 0,6W