Whirlpool KHPF 7510/I Mode d'emploi Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
Category II2H3+
Electric Power: 230 V - 50 Hz
If a hood is to be installed above the hob, refer to the hood
installation instructions to ensure the correct height above
the hob.
Note: If the distance “A” between the kitchen wall cabinets is
between 600 and 730 mm, height “B" shall be at least 530
mm.
If the distance “A” between the kitchen wall cabinets is wider
than the hob’s width, height “B shall be at least 400 mm.
Hood and cabinetry clearances (mm)
Injector table
6
Type of gas used Type of
burner
Injector
label
Control
primary air
(X) (mm)
Nominal
heat flow
kW
Nominal
consumption
Reduced
heat flow
kW
Gas pressure (mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
wok
semi-fast
auxiliary
145
95
78
6
-
-
4,20
1,65
1,00
400 l/h
157 l/h
95 l/h
1,40
0,40
0,30
17 20 25
LIQUID
PETROLEUM
GAS (Butane)
G30
wok
semi-fast
auxiliary
100
65
50
11
-
-
4,20
1,65
1,00
305 g/h
120 g/h
73 g/h
1,40
0,40
0,30
20 28-30 35
LIQUID
PETROLEUM
GAS (Propane)
G31
wok
semi-fast
auxiliary
100
65
50
11
-
-
4,20
1,65
1,00
300 g/h
118 g/h
71 g/h
1,40
0,40
0,30
25 37 45
Type of gas used Configuration model Nominal heat flow kW Overall nominal
consumption
Required air (m
3
) for
the combustion 1 m
3
of
gas
G20 20 mbar 4 burners 8,5 809 l/h 9,52
G30 28-30 mbar 4 burners 8,5 618 g/h 30,94
G31 37 mbar 4 burners 8,5 607 g/h 23,80
5019_719_01132_GB 1-06-2007 14:30 Pagina 6
Vue de la page 5
1 2 3 4 5 6 7 8 9 10 11 ... 15 16

Commentaires sur ces manuels

Pas de commentaire