HB 530
HOB INSTRUCTIONS Destination
GB
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
5019 619 01120/A
PT ES GBIT
HOB DIMENSIONS (mm)
Operation of burners with safety device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anti-clockwise to the
large flame setting .
• At the same time, press the button with the star .
The spark plug gives out a spark that causes the burner
to ignite.
• Once the burner is lit, keep the knob pressed for about
10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operation.
Note:
-
Should particular local conditions of the delivered gas
make the ignition of the burner difficult, it is advisable to
repeat the operation with the knob turned to the small
flame setting .
The burner safety system serves to prevent the emission of
gas if the flame should be extinguished accidentally (draughts,
interruptions in gas supply, dousing with liquids, etc.).
NOTES: In case of installation of a hood above the cooktop, please refer to the hood instructions for
the correct distance.
1
4
2
3
5
6
7
8
9
10
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
10.
Electric ignition button
Symbols
Shaded circle Tap closed
Large flame Maximum opening/delivery
Small flame
Minimum opening or
reduced delivery
INJECTORS TABLE CATEGORY II2H3+
ELECTRIC SUPPLY: 230V ~ 50Hz
BEFORE USING THE COOKTOP
These instructions are only valid for above mentioned
Country destinations and also on the appliance.
•
Keep the packaging material (plastic bags, polystyrene
parts, etc.) out of the reach of children, as they are
potentially dangerous.
•
Use a proprietary detergent to clean the stainless steel hob
and remove any grease and food deposits. Before using the
hob, be sure to remove any adhesive labels.
•
Check whether the cooktop has been damaged during
transport.
•
Ensure that the installation and gas/electrical
connections are performed by a qualified technician,
following the manufacturer's instructions and in
compliance with current local safety regulations.
SUGGESTIONS FOR ENVIRONMENT PROTECTION
Packing
The packaging material is 100% recyclable and marked with the
recycling symbol ( ).
Products
This appliance is marked according to the European directive
2002/96/EC on Waste Electrical and Electronic Equipment (WEEE).
By ensuring this product is disposed of correctly, you will help prevent
potential negative consequences for the environment and human
health.
The symbol on the appliance or accompanying documentation
indicates that this product should not be disposed of as unsorted
municipal waste but must be taken to a collection point for the
treatment of WEEE. Dispose of in accordance with local standards
governing waste disposal.
For further information on the treatment, recovery and recycling of
this appliance, contact your competent local authority, the collection
service for household waste or the shop where you purchased the
appliance.
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity
kW
Rated
consumption
Reduced
heat
capacity kW
Gas pressure (
mbar)
min. rat. max.
NATURAL GAS
(Methane) G20
large
medium
small
Y 115
H2 98
X 72
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
LIQUID PETROLEUM
GAS
(Butane) G30
large
medium
small
87
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
20 28-30 35
LIQUID PETROLEUM
GAS
(Propane) G31
large
medium
small
87
65
50
3.00
1.65
1.00
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
25 37 45
Type of gas used Appliance model Total rated heat
capacity
kW
Total rated
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 4 gas 7.30 695 l/h 9.52
G30
28-30 mbar 4 gas 7.30 531 g/h 30.94
G31
37 mbar 4 gas 7.30 521 g/h 23.80
Commentaires sur ces manuels