N C
M Y
INSTALLATION
Adaptation to different types of gas
If a gas different from that indicated on the label
is used, adapt the cooktop to this new function.
To replace the injectors consult the After-Sales
Service or a trained technician.
Injectors not supplied can be obtained from the
After-Sales Service.
1. Connect the cooktop to the on-off tap with a
tube which is suitable for the gas to be used
according to the regulations in force.
2. Replace the injectors (see Product Card),
proceeding as follows:
x Remove the grids (A).
x Extract the burner bodies (B).
x With a Ø 7 socket spanner (C) unscrew the
injector to be replaced.
x Replace with the injector provided for t he
new t ype of gas and reassemble in (D).
x Reassemble the burner bodies and the girds.
x Cancel the calibration indication (set for ....
gas) on the rating plate and position the
plate for the new type of gas near the gas
mains connection. This is to be found in the
bag of injectors supplied.
3. Select the type of gas (see Product Card) on
the basis of the injectors selected in point 3,
proceeding as follows:
x Make sure that the button
U
(see Product
Card) is OFF.
x Turn all the knobs to the minimum search
position.
x Keep button -
)
pressed and press button
+
=
3timeswithin 5 seconds then
release. The display shows the type of gas
adjusted in the factory or the last gas
selected.
If the buttons are not selected within 10
seconds, the procedure finishes without
changes.
x To select a different type of gas press
button +
=
choosing according to the
sequence C1 f C2 f C3 f C4 f C5.
f
x To save the type chosen, keep button -
)
pressed down and press button +
=
3 times within 5 seconds then release: the
saving is confirmed by an acoustic signal.
4. Automatically adjust the minima (see Product
Card).
58
Commentaires sur ces manuels