+3+E2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
.xam.tar.nimRFEBWk
NATURAL GAS
(Methane) G20
Rapid
F2 118
3.00286 l/h0.800.60
17 20 25
Semi-rapid Z 95 1.65 157 l/h0.450.35
Auxiliary X 72 1.0095 l/h0.350.30
NATURAL GAS
(Methane) G25
Rapid Y115 3.00332 l/h0.60
20 25 30Semi-rapid Z 95 1.65 183 l/h0.35
AuxiliaryX 72 1.00111 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid853.00218 g/h0.60
20 28-30 35Semi-rapid 63 1.65 120 g/h0.35
Auxiliary501.00 73 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid853.00214 g/h0.60
25 37 45Semi-rapid 63 1.65 118 g/h0.35
Auxiliary501.00 71 g/h0.30
Type of gas used Model conguration
3 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar 1 R - 1 SR - 1 AUX 5.65 538 l/h9.52
G25 25 mbar 1 R - 1 SR - 1 AUX 5.65 626 l/h8.187
G30 28-30 mbar 1 R - 1 SR - 1 AUX 5.65 411 g/h 30.94
G31 37 mbar 1 R - 1 SR - 1 AUX 5.65 403 g/h23.80
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz 1500 W