ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, proceed as
follows:
• tighten screw to reduce the flame height (-)
• loosen screw to increase the flame height (+)
The adjustment must be performed with the tap in minimum gas
setting position (small flame) .
• The primary air of the burners does not need to be adjusted.
• At this stage, light up the burners and turn the knobs from max
position to minimum position to check flame stability.
Upon completion of adjustment, reseal using sealing wax or an
equivalent material.
DIMENSIONS OF COOTOP AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the
correct distance.
INJECTORS TABLE CATEGORY II2L3B/P
ELECTRIC SUPPLY: 230V ~ 50Hz
Ty p e o f g a s u s e d
Ty p e o f
burner
Injector
marking
Rated
thermal flow
rate kW
Rated
consumption
Reduced
heat
capacity kW
Gas pressure
(mbar)
min. rat. max.
NATURAL GAS
(Methane) G25
rapid
semirapid
auxiliary
129
108
78
3.00
1.90
1.00
332 l/h
210 l/h
111 l/h
0.60
0.35
0.30
20 25 30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
rapid
semirapid
auxiliary
87
70
50
3.00
1.90
1.00
218 g/h
138 g/h
73 g/h
0.60
0.35
0.30
25 30 35
Type of gas used Model configuration
4 BURNERS
Rated thermal
flow rate kW
To t a l r a t e d
consumption
Air required (m
3
) for
burning 1m
3
of gas
G25 25 mbar
1 R - 2 SR - 1 AUX 7.80 863 l/h 8.187
G30/G31 30 mbar
1 R - 2 SR - 1 AUX 7.80 567 g/h 30.94