240-VOLTELECTRIC DRYERUse & Care GuideFor questions about features, operation/performance,parts, accessories or service, call: 1-800-253-1301.or v
10When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked en
111. Loosen or remove center terminal block screw.2. Place the hooked end of the neutral wire (white or center wire) of power supply cable under the c
12Determine vent path Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest num
13Level DryerCheck the levelness of the dryer. Check levelness first side to side, then front to back.If the dryer is not level, prop up the dryer usi
14DRYER USEStarting Your DryerWARNING: To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before
15ControlsThe control panel is simple to understand and easy to operate. The illustrations below define the knobs and buttons, and the paragraphs def
16See following table for recommended cycles and temperature settings.Timed DryUse this cycle to get up to 60 minutes of heated drying time or to comp
17IMPORTANT: Do not run the dryer with the lint screen loose, damaged, blocked or missing. Doing so can cause overheating and damage to both the drye
18TROUBLESHOOTINGFirst try the solutions suggested here and possibly avoid the cost of a service call...Dryer OperationDryer will not run Has a hous
19 Is the dryer located in a room with temperature below45ºF (7ºC)? Proper operation of dryer cycles requires temperatures above 45ºF (7ºC). Is the
2TABLE OF CONTENTSDRYER SAFETY...3INSTALLATION REQUIREMENTS...
W10189310B© 2008 Whirlpool CorporationAll rights reserved ® Registered Trad emark/TM Trademark of Whirlpool U S A4/08Printed in ItalyWHIRLPOOL CORPORA
3DRYER SAFETYYou can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don'tfollow All
4INSTALLATION REQUIREMENTSTools and PartsTools neededGather the required tools and parts before starting installation. Read and follow the instruction
5Installation ClearancesThe location must be large enough to allow the dryer door to open fully.Dryer Dimensions*Most installations require a minimum
6Electrical RequirementsIt is your responsibility To contact a qualified electrical installer. To be sure that the electrical connection is adequate
7Venting RequirementsWARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.IMPORTANT: Observe all governing codes and ordinances.
8INSTALLATION INSTRUCTIONSElectrical ConnectionPower Supply Cord Direct Wire1. Disconnect power.2. Remove the terminal block cover. 3. Unscrew the str
96. Replace strain relief (with power cord inserted) back into the terminal block cover. Do not tighten strain relief nut.7. Now complete installation
Commentaires sur ces manuels