5019 300 01063
LIGHTING THE BURNERS
• To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting .
• Press the knob against the control panel to ignite the burner.
• After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling over,
etc.).
• The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit,
wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For optimum burner performance, observe the following
rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
1. Removable panstand grids
2. Auxiliary burner
3. Semirapid burner
4. Rapid burner
5. Semirapid burner
6. Rapid Burner
7. Auxiliary burner control knob
8. Semirapid burner control knob
9. Rapid burner control knob
10. Semirapid burner control knob
11. Rapid burner control knob
SYMBOLS
Tap closed
Maximum flame
Minimum flame
Burner Pot Ø
ultra-rapid From 24 to 26 cm
Rapid From 24 to 26 cm
semi-rapid From 16 to 22 cm
Auxiliary From 8 to 14 cm
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
N.B: If the distance "A" between the wall cabinets is between 600 mm and 730 mm, the height "B" must be
a minimum of 530 mm. If the distance “A” between the wall cabinets is greater than the width of the
hob, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the
cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Type of gas used Type of burner Injector
marking
Nominal
heating
capacity kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure (mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
ultra-rapid
Rapid
semi-rapid
Auxiliary
136
128
95
78
3.50
3.00
1.65
1.00
333 l/h
286 l/h
157 l/h
95 l/h
0.60
0.60
0.35
0.30
17 20 25
LIQUID
PETROLEUM GAS
(Butane) G30
ultra-rapid
Rapid
semi-rapid
Auxiliary
94
87
67
50
3.50
3.00
1.65
1.00
254 g/h
218 g/h
120 g/h
73 g/h
0.60
0.60
0.35
0.30
20 28-30 35
LIQUID
PETROLEUM GAS
(Propane) G31
ultra-rapid
Rapid
semi-rapid
Auxiliary
94
87
67
50
3.50
3.00
1.65
1.00
250 g/h
214 g/h
118 g/h
71 g/h
0.60
0.60
0.35
0.30
25 37 45
Type of gas used Model
configuration
Nominal heating
capacity kW
Total nominal
consumption
Air required (m
3
) for burning
1m
3
of gas
G20 20 mbar 5 burners 10.8 1028 l/h 9.52
G30 28-30 mbar 5 burners 10.8 785 g/h 30.94
G31 37 mbar 5 burners 10.8 771 g/h 23.80
GMR 7511 PRODUCT SHEET
To ensure best use of the hob, please read these instructions for use carefully and keep them for future reference.