GB
-1-
Chart
PROGRAMME SELECTION BUTTON
Press button “P” (repeatedly) until the indicator of the required programme lights
up (see “Table of programmes” below).
ON
BUTTON
OFF
BUTTON
START BUTTON
The indicator lights up during operation, flashes when a fault occurs and goes off at
the end of the programme.
START BUTTON RESET FUNCTION
Press this button for at least 2 seconds; the selected programme and options are
cancelled. Main failure displays (repeated flashing of the START indicator lamp) can
be cancelled by RESETTING. Detailed instructions are given in chapter “What to
do if...”.
(see at right for options description)
1) Programme data obtained in conformity with European standard EN 50242, obtained under normal conditions (without additional
options) and may vary depending on conditions. Differences of up to 20 minutes are possible with sensor programmes as a result of
the appliance’s automatic calibration system.
2) Reference programme for energy label in compliance with EN 50242 regulations. - Note for Testing Institutes: for detailed information
on the EN/Standard loading comparison te
st and other tests,
contact the following address: “nk_cu[email protected]”.3) The antibacterial action has been tested by the Institut Pasteur of Lille (France), based on the NF EN 13697 standard of November 2001.
Table of programmes
Detergent
Consumption
P
Programmes
Available
options
Loading instructions Litres kWh
Minutes
1)
1
Pre-Rinse cold
— Crockery to be washed later. — 5.0 0.02 10
2
Quickwash 40°C
—
Lightly soiled crockery, with no
dried-on food. * Use of tablets
not recommended.
X * 13.0 0.70 30
3
Eco
2)
50°C
Half
load
Normally soiled crockery.
Energy-saving programme.
X 15.0 1.05 165
4
Antibacterial
3)
—
Normally or heavily soiled
crockery, with additional
antibacterial action. Programme
interruption (e.g. due to door
opening) can compromise
elimination of germs.
X 16.0 1.75 120
5
Intensive 70°C
—
Recommended programme for
heavily soiled crockery, especially
suitable for pots and pans.
X 17.0 1.65 145
5019 396 01765ADG 7557
Options and display description
BEFORE USING THE APPLIANCE FOR THE
FIRST TIME CAREFULLY READ THIS QUICK
REFERENCE GUIDE AND THE INSTALLATION
INSTRUCTIONS! THE GUARANTEE IS NOT
APPLICABLE IF FAULTS ARE CAUSED BY
INCORRECT USE OF THE APPLIANCE.
RINSE AID INDICATOR
When lit, the rinse aid
dispenser needs to be refilled.
SALT INDICATOR
When lit, the salt reservoir
needs to be refilled.
HALF LOAD/MULTIZONE BUTTON
Half load can be used for the top and bottom racks.
Select the programme then press the “Half load”
button. The indicator lights up, and goes off at the
end of the programme. This function can be used
with the programmes indicated in table of
programmes.